Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire from Fireworld

Gas Combi Boilers

Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire

Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire

Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire
Product No: FW3409

Bookmark and Share

  • High efficiency BBU with a modern electric fire connection
  • Only high efficiency back boiler available in the UK and has a grad A efficiency rating to save energy and costs
  • Back boiler produces a 15kW maximum heat output which adapts to the amount of demand
  • Boiler controls are located on the fireplace and are simple to use
  • Condensate pump is built in which will ease installation
  • Lightweight fan reduces noise
  • Created to work specifically with the Valor Dimension range of electric fire
  • Valor Dimension Regalia included
  • traditional polished arch finish
  • Holographic fuel bed provides a unique 'real fire effect'
  • Fire provides a heat output of 1 and 2kW
  • Remote control provided for the fire which lets user control the output of the fire and to turn it on/off
  • Inset depth of 144mm
  • Spacer available at an extra price which increases the outset depth by 50mm
  • 2 flexible concentric flue kits available at 10m or 12.5m lengths and include terminal, flue duct adaptor, air cowl, air duct collar, air duct clamp and chimney plate
  • Right hand plumb kit available if the existing pipe work is connected on the right hand side
  • Flue pull cone is available as an extra to ease installation

Fireworld Delivery

Free Delivery!

Estimated delivery 10 working days

Need a brochure for the Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire?
click fire-fireplace brochures

was £1,736.00
NOW £1,330.00


Options | Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire

Bermuda 10m Flexible Flue Kit (including terminal)
Bermuda 10m Flexible Flue Kit (including terminal)
add £256.00
Bermuda 12.5m Flexible Flue Kit (incl terminal)
Bermuda 12.5m Flexible Flue Kit (incl terminal)
add £307.00


Controls | Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire

Valor Dimension Remote Control
Valor Dimension Remote Control

Comes standard within the price of this fire
included


Extras | Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire

Dimension Regalia spacer kit
Dimension Regalia spacer kit

Increases outset depth by 50mm, PC code: 137611
add £21.00
Baxi flexible flue pull cone
Baxi flexible flue pull cone

add £62.00
Baxi Bermuda right hand plumb kit
Baxi Bermuda right hand plumb kit

add £77.00




Specifications | Baxi Bermuda HE Back Boiler & Valor Regalia Electric Fire


External Dimensions
Hsee tablemmWsee tablemmDsee tablemm

OutPut
Boiler provides a maximum heat output of 15kW and electric fire has heat outputs of 1kW & 2kW

Fire Diagram
 

Details
High Efficiency condensing back boiler which connects through a modern electric fire

Flue
10m or 12.5m flexible concentric flues available

Notes

Fire Specs
Height
Width
Inset
Depth
Outset
Depth
Bermuda BBU HE & Valor Classica
615
512
144
51
Bermuda BBU HE & Valor Dream
636
518
144
79
Bermuda BBU HE & Valor Innova
632
542
144
38
Bermuda BBU HE & Valor Lyrica
612
510
144
74
Bermuda BBU HE & Valor Nano
616
512
144
49
Bermuda BBU HE & Valor Regalia
720
600
144
45


See Baxi Brochure for more details

Note: All sizes are in millimetres. This electric fire requires a 13amp socket to plug into on installation and the heat is provided by a fan heater under the canopy as shown in the picture above. In instances where there is insufficient depth to recess the fire in to the wall, a 3" inch deep rebated surround will be required or you will need to purchase the optional extra spacer kit code 0584081 (see options section near the top of this page for details.

Please ensure to have a survey carried out by a Gas Safe Register registered gas installer to check and certify the compatibility of your chimney or flue with this fire before making any purchase to avoid disappointment. Where there is insufficient depth a deep rebate surround may be required.
It must be carried out in accordance with the relevant requirements of the Gas Safety (Installation & Use) Regulations; The appropriate Building Regulations either The Building Regulations, The Building Regulations (Scotland), Building Regulations (Northern Ireland); The Water Fittings Regulations or Water Byelaws in Scotland; The Current I.E.E. Wiring Regulations. If a false chimney breast is intended to house the boiler, a simulated builders opening, within the breast, must be provided.

To accommodate the firefront without the need for additional spacers, there must be a gap of at least 95mm from the surround or finished face to the front of the boiler. If necessary this gap can be increased by the use of frame extension kits. Each extension increases the effective depth of the opening by up to 50mm.

Only one of the two available MULTIIFIT vertical concentric Flexi Flue kits approved for use with the boiler can be used (10m kit 720101701 or 12.5m kit 720102001). Any proprietary flue systems, terminals, adaptors etc. MUST NOT BE USED. The flue must have a minimum vertical height of 3m and have no bends greater than 45°. No horizontal runs are permitted. It must also be a minimum of 150mm from any other terminals or obstructions (A). When adjacent to windows or openings on pitched or flat roofs it must be at least 600mm away (B). A minimum dimension of 2000mm must be maintained when below windows or openings in pitched roofs (C)

The gas installation should be in accordance with relevant standards. In GB this is BS 6891. In IE this is I.S. 813 “Domestic Gas Installations”. The connection at the appliance is 15mm copper tail located at the rear of the gas tap.
Ensure the discharge of condensate complies with any national or local regulations in force. Metal pipework is NOT suitable for use in condensate discharge systems. Any pipe fitted externally must be kept as short as possible to minimise the potential of freezing and must be insulated using waterproof material. When discharging condensate into a soil stack or waste pipe the effects of existing plumbing must be considered.

WARNING: The appliance must be earthed. The input cable for the appliance should be 0.75mm2 to IEC Code 227 (heat resistant). The system external controls and the boiler must be supplied by the same isolator. The boiler MUST NOT be connected to the same supply as the firefront as their fuse ratings are different.
The CO2 must be only be checked and adjusted to set the valve if a suitable calibrated combustion analyser is available, operated by a competent person.